Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01443
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/24/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
10/19/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEM 1 OF 10/06/06 NOT DONE 2) STUDS WITH CS20 STRAPS MUST HAVE RSP4/H2.5 CLIPS AT BOTTOM 3) STRAP NON OVERLAPPING DBL TOP PLATES |
|
10/10/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER FRAMING SUPER |
|
10/06/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEARWALL GARAGE NOT NAILED 6" ON CENTER AT EDGES 2) SHEARWALL NAILING FRONT OF GARAGE NOT 6" ON CENTER 3) EAST WALL MISSING CLIPS EVERY OTHER STUD 4) GLU LAM WEST SIDE NOT STRAPPED 5) DETAIL 1/D6 NEEDS TO BE ADDRESSED-EXTERIOR WALLS MISSING H.25 BOTTOM & TOP 6) NO ACCESS TO ROOF 7) STOPPED INSPECTION |