Permit: T06CM01384

Parcel: 10612017R

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
04/20/2006 BUILDING - FINAL Approved IVRS - Inspection :*
04/19/2006 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
03/29/2006 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1. RESTROOMS DO NOT MEET CODE YOU WILL NEED TO BRING THEM UP TO CODE BEFORE CALLING FINAL.
SPECIFICALLY
A) IBC 1210.1 - FLOORS SHALL HAVE A SMOOTH, HARD,
NON- ABSORBENT SURFACE EXTENDING UP WALLS A
MINIMUM OF 6".
AND
B) 1210.2 WALLS WITHIN 2' OF URINALS OR WATER CLOSETS MUST HAVE A SMOOTH, HARD, NON-ABSORBENT SURFACE
PAINT ON SHEETROCK IS NOT OK