Permit: T06CM01380

Parcel: 122173860

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/23/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
08/15/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ADD; REPLACE WATER HEATERS TO YOUR PERMIT.
PROVIDE DIELECTRIC UNIONS AT WH
REMOVE EXCESS FLUX FROM SOLDER JOINTS
INSTALL SEDIMENT TRAPS AT WHS AND FURNACE
PROVIDE HB VAC BREAKERS ON ALL HOSE BIBS
SEE NOTES FROM LAST INSPECTION.
07/11/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. NOT INSTALLED PER PLAN -- SOME OF THE ITEMS INCLUDE:
DELTA WRIST BLADE HANDLES
LAVATORY TO BE CARRIER HUNG
LOOSE KEY ANGLE STOPS
FLUSH HANDLE ON WRONG SIDE OF WATER CLOSETS
BLDG. INSP. MAY NOTE CLEARANCE ON H.C WATER CLOSETS.