Permit: T06CM01374

Parcel: 141311340

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01374

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/29/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/16/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) TRUSS REPAIRED
2) NEED PORCH INSTALLED
07/13/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval 1) REPAIR TRUSS A-2 MARKED ON FLOOR CHECK AT INTERMEDIATE INSPECTION
07/10/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE LAST INSPECTION
2) NO UFER
07/05/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL ALL SHEAR BLOCK PANELS TO ROOF GAP TO BIG BETWEEN TOP OF PANEL AND ROOF DECK USE NAILS LONG ENOUGH TO PENETRATE BLOCKS
3) CRACK IN TRUSS, MARKED ON FLOOR HAVE TRUSS MANUFACTURER INSPECTION
40 RAT RUNS MISSING THROUGHOUT
06/22/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PANELS TO ROOF SHIM SPACE DECK TO PANEL
2) HORIZONTAL NAILING REAR SHEAR TRANSFER
3) RAT RUNS ? ELEV.
4) CHECK CRACK IN TRUSS MEMBER-MARKED ON FLOOR
5) NAIL 6" ON CENTER SHEAR TRANSFER 6D COMMONS