Permit: T06CM01371

Parcel: 131090620


Addresses:

5791 E 24TH ST #01

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/09/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
WATER TEST WATER PIPING & WASTE & VENT THRU ROOF OK
10/09/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. WASTE & VENT PIPING TO BE TESTED THRU ROOF.
2. ABS & PVC CANNOT BE INTERMINGLED WITHOUT CORRECT APPROVED TRANSITION COUPLING. PROVIDE LIKE FOR LIKE MATERIALS FOR WASTE & OVERFLOW FOR TUBS.
3. PROVIDE WATER DISTRIBUTION PER PLAN.
4. LAVS TO HAVE LONG RADIUS DRAINAGE FITTINGS FOR STUB OUT OF WALL AND DRAIN ARM MAY ONLY HAVE 135 DEG. CHANGE OF DIRECTION.
5. PROVIDE MINIMUM 18" WEIR OF TRAP TO WASHER BOX INLET AND USE FACTORY MADE P-TRAP.