Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM01371

Parcel: 131090620


Addresses:

5791 E 24TH ST #01

Inspection Status: Approved

Inspection History: PLUMBING - PRE SLAB

Date Description Inspector Results Comments
06/12/2006 PLUMBING - PRE SLAB Approved IVRS - Inspection :*
06/02/2006 PLUMBING - PRE SLAB Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. THIS IS A NEW INTALLATION PROVIDE SOLVENT WELD COUPLINGS AT STOOL RISERS. RETEST.
THE COUPLINGS YOU USED ARE NOT APPROVED PLASTIC TO PLASTIC.
REST OF ROUGH SOIL OK
PLEASE CALL IN 03005 FOR REINSPECTION 03015 IS USED FOR INSPECTION PRIOR TO CONCRETE POUR FOR PIPE WRAPS, TRAP PRIMERS, FLOOR DRAIN & SINKS