Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01352

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/13/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/12/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2 NAILS REQUIRED IN BOTTOM PLATE OF WIND BRACES
2) POSITIVE CONNECTION REQUIRED AT PATIO
3) CLIP 3 PT BEARING TRUSSES AT MID SPAN
4) REMOVE CLIPS AND SHIMS AT NON-BEARING WALLS
5) HINGE BRACES NOT PER PLAN
6) ROOF NOT INSPECTED
06/07/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLANS/STOPPED INSIDE
2) GARAGE HOLDOWNS REQUIRE 8" STEM AND MINIMUM 4 1/2" FROM CORNER PER PLAN
3) NO LADDER
4) INCOMPLETE-SUPER AND APPROPRIATE SUB TO WALK ALL HOUSES AND COMPLETE PRIOR TO INSPECTIONS
05/30/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING NAILING ON ROOF, NAIL SHEAR PANEL BLOCKS
2) WIND BRACES MISSING NORTH SIDE, TWO NAILS TOP AND BOTTOM PLATES
3) 48" STRAP GARAGE SIDES
4) GABLE AND NAILING TO TOP PLATE SHEAR TRANSFERS, NOT DONE
5) HORIZONTAL SHEAR NAILING REAR
6) REAR SCISSOR TRUSSES SC02, TURNED END FOR END 3 PT
7) SHIM ALL 3 PT BEARING
8) P.A.'S REAR IN WRONG PLACE
9) NO PORCH ?