Permit: T06CM01350

Parcel: 11613116H

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/04/2008 BUILDING - FINAL Approved IVRS - Inspection :*
07/29/2008 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER LINE DEPTH AT SOUTH HOSE BIB NEEDS TO BE 12" DEEP
2) NEED TO INSULATE ALL HOLES AND SPACES IN EXTERIOR BLK WALL
3) NEED TO LOWER CLEANOUT IN FRONT YARD AND APPROVED COVER
4) COMPLETE CLEANOUT ON EXT. WEST WALL
5) TERMINATION OF TPR AND CONDENSATION LINE NEED 90 DEGREE
6) POST ADDRESS WERE VISIBLE FROM STREET
7) NEED GFI RECEPTACLE AT HVAC UNIT
05/30/2008 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*