Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/05/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED LADDER TO VERIFY 1/2" X 10" BOLTS ON RAFTER TO TOP PLATE 2) MISSING H2.5 AT 2 PLACES ON EAST WALL CONNECTING TO RAFTERS 3) SUPPORT BEAM AT PORCH NOT PER PLAN. NEED CONNECTION TO SUPPORT POST 4) NEED LADDER TO ACCESS ROOF |