Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM01350

Parcel: 11613116H

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/10/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/05/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED LADDER TO VERIFY 1/2" X 10" BOLTS ON RAFTER TO TOP PLATE
2) MISSING H2.5 AT 2 PLACES ON EAST WALL CONNECTING TO RAFTERS
3) SUPPORT BEAM AT PORCH NOT PER PLAN. NEED CONNECTION TO SUPPORT POST
4) NEED LADDER TO ACCESS ROOF