Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/23/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 05/17/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. M.C CONNECTOR AND PROPER TERMINATION INTO LIGHT FIXTURES (BOTH) IS REQUIRED. |
|
| 04/20/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. METAL BOXES NEED TO BE GROUNDED 2. CONDUCTORS LEAVING BOX NEED TO ENTER INTO TIGHT FIXTURE. RIGHT NOW, THEY GO THROUGH DRYWALL AND OUTSIDE J-BOX. |
|
| 04/10/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. NEED TO PAY REINSPECTION FEE 2. NEED TO FINISH CORRECTIONS -- #2 FROM PREVIOUS INSPECTION. MC NEEDS PROPER TERMINATION INTO LIGHT FIXTURE CAN'T HAVE OPEN WIRING NEC 330 |
|
| 03/20/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. PROVIDE PROPER ENTRY INTO LIGHT FIXTURES FOR RACEWAYS. 2. TIGHTEN ALL DEVICES TO SURFACE 3. INSURE THAT EMERGENCY LIGHTING IS WORKING PROPERLY |