Permit: T06CM01336

Parcel: 107030310


Addresses:

2566 N JORDAN DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/13/2006 FRAMING Approved IVRS - Inspection :*
06/06/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
05/26/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO REFEE ASSESSED AT THIS TIME
2) SECURE ROMEX TO WITHIN 12" ALL BOXES
3) 10 POUND GAS PRESSURE TEST REQUIRED
4) EVAP COOLER TO BE REMOVED
5) KITCHEN ELECTRIC CIRCUITS TO BE 20 AMP #12 WIRE
6) INSTALL H20 HEATER CABINET, PTR LINE AND FLU PIPE
7) PLAN CALLS FOR 3/4" GAS LINE TO ROOF UNIT
8) ELECTRIC NOT RUN TO ROOF TOP UNIT
9) ALL ELECTRIC EXPOSED BELOW 8' TO BE IN CONDUIT
10) ALL ELECTRIC J-BOXES TO BE ACCESSIBLE
11) INSTALL 220 VOLT WIRES GARAGE IN CONDUIT
12) MAKE UP ALL GROUNDS ELECTRIC BOXES
13) COMPLETE EXHAUST HOOD DUCT KITCHEN
14) SINK TRAP ARM INADEQUATE SLOPE
15) H20 TEST DWV THROUGH ROOF
16) SECURE PLASTIC ELECTRIC BOXES TO WALLS
17) SLIP FITTING NOT ALLOWED DRAIN TUB-MUST BE GLUED FITTING
18) ALL H20 LINES BELOW SLAB TO BE REROUTED OVER HEAD
19) STOPPED INSPECTION
20) COMPLETE ALL AND RECALL
05/16/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INCOMPLETE-RECALL WHEN READY
03/30/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) ALL INTERMEDIATE MUST BE COMPLETE BEFORE FRAMING INSPECTION
03/29/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) LOCKED-NO ACCESS
2) PLANS/PERMIT ?? RECALL