Permit: T06CM01333

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/02/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
CORRECTIONS MADE OK
OK TO COVER ALL AREAS
11/01/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
10/30/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
10/26/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
- 180 DEG. CHANGE OF DIRECTIONS REQUIRE CLEAN OUT OR USE 1/8" BENDS.
- SWEEPS REQUIRED ON PIPING BELOW FLOOD LEVEL OF FIXTURE, WASTE & VENT.
- SUPPORT TRAP ARMS
- TEST DRAIN FOR SOFTENER, USE DOUBLE WASHER BOX.
- TRAP ARM CANNOT REDUCE.
10/25/2006 PLUMBING - INTERMEDIATE Cancelled IVRS - RI canceled
10/23/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*