Permit: T06CM01331

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/02/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
CORRECTIONS MADE OK
OK TO COVER ALL AREAS
11/01/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
10/30/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
10/26/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
10/25/2006 PLUMBING - INTERMEDIATE Cancelled IVRS - RI canceled
10/23/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
ABS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES, THEN NO MORE THAN FOUR FEET BETWEEN HANGERS.
USE APPROVED STRAPS
REQUIRE 18" OF COPPER AT SERVICE AND WATER HEATER
SUPPORT TRAP ARMS
HORIZ X HORIZ CHANGE OF DIRECTION TO BE A SWEEP
04/20/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. ABS MAY NOT BE RUN IN THE FOOTING
2. CORRECT BACKPITCHED SECTION.
04/19/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UPPER FLOOR ROUGH PLUMBING OK
04/17/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. OWNER TOOK OPTION FOR DOWNSTAIRS BATHROOM.
NO APPROVED PLAN ON SITE.
INSTALLED PER REDLINES.
LOCATION OF UPSTREAM MANHOLE MANDATES A "DUAL" ROUGH IN
LOWER ROUTH INSTALLED PER REDLINES
OK TO COVER SUBJECT TO REVISED APPROVED PLAN
OK TO PLACE 2ND FLOOR PLUMBING AND RECALL FOR INSPECTION.
04/14/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. NO APPROVED PLAN
SITE PLAN APPROVED IN ERROR (140 BACKWATER VALVES)
2. PLUMBER PROVIDED 8 1/2" x 11" "AS BUILT"
PLUMBER DIDN'T PROVIDE WRITTEN ELEVATIONS OF FLOOR LEVEL AND OVERFLOW OF UPSTREAM MANHOLE.
3. PLUMBER TO LAY LOWER ROUGH ON A FIRM BED, SHADE THE PIPE AND HAVE IT INSPECTED, THAN THE PLUMBER WILL LAY THE UPPER ROUGH ON A FIRM BED, SHADE THE PIPE AND CALL IT IN FOR INSPECTION.