Permit: T06CM01331

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
05/22/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
11/16/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK INTERIOR ELECTRICAL COVER
11/07/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. NEUTRALS ON 3 WIRE HOME RUNS NEED TO BE PIGTAILED NEC 210?
2. MOVE DRYWALL AWAY FROM WALLS SO I CAN SEE WALLS.
3. MAX 12' BETWEEN RECEPTACLES ALONG WALL --
NEC 210.52 A1
4. FINISH LOW VOLTAGE WIRING (ALL)
5. SMOKE DETECTORS NEED TO BE MINIMUM 3 FEET FROM HVAC VENTS -- SUPPLY OR RETURN

REINSPECTION FEE WILL BE CHARGED IF CORRECTIONS NOT COMPLETE NEXT INSPECTION.
11/01/2006 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
DO NOT CALL BEFORE READY
10/31/2006 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*