Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM01329
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/18/2007 | FRAMING | Approved | IVRS - Inspection :* | |
01/16/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) STUCCO LATHE DEGRADED BY SUN EXPOSURE |
|
01/03/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OUTSIDE HOSE BIB REQUIRED ANTI-SIPHON VALVE 2) NO TRACER ON YARD WATER 3) TOILET ABOVE POWDER ROOM NOT PROPERLY VENTED 4) STAIR RISE EXCEEDS 3/8" DIFFERENCE AND 7 3/4 RISE BOTH STAIRS 5) PUT HANGERS ON TRUSSES 6) NAIL PROTECT WIRES 7) NAIL SHEARWALL LADDER BACK TO WALL 8) NAIL PROTECT PLUMBING 9) SUPPLY TO FIRST FLOOR KINKED REQUIRES 1 DUCT ? 10) AC SECONDARY DRAIN MUST BE IN CONSPICOUS LOCATION 11) MISSING ANCHOR BOLT DEN 12) SEAL VAPOR BARRIER 13) BAD GAUGE-NO GAS TEST |