Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM01329

Parcel: 141095220

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01329

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/17/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/09/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 4 EACH GARAGE FRONT HOLDOWNS MISSING
2) PROVIDE ALTERNATE HOLDOWN
07/26/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO DRY IN
2) ITEM 1 OF 7/20/06 NOT DONE
07/25/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO CHANGE FROM 7/20/06
07/20/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE MAS STRAPS MISSING USE LTT20 ALT
2) STRAP REAR NON OVER LAPPING DBL TOP PLATES
3) H2.5 CLIP PORCH LEDGER TO FLOOR TRUSS
4) SHIM FLOOR ? UNDER SOUTH 5040
5) CLIP POSTS
6) NAIL SHEAR
7) NO LADDER TO ROOF
8) FRONT MISSING SHEAR PANEL