Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/18/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LOOSE SHEETS GARAGE 2) COMPLY WITH DETAIL 3/4 8D NAILS 6" ON CENTER DIAPHRAM 3) COMPLY WITH PREVIOUS INSP. BRACED WALL ? 4) 2 POINT BEARING TRUSS ALLOW 1/24 ? MID WALL |
|
| 09/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL BRACED PANELS MUST REACH TOP/TOP PLATES 2) INSTALL 16"-24" PANELS WITH BLOCKING OR REPLACE OSB AT BRACED PANELS TO REACH TOP PLATES 3) PROVIDE SAFE ACCESS TO ROOF 4) PROVIDE TRUSS CALCS |