Permit: T06CM01314

Parcel: 141134160

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
07/19/2006 ROOF NAILING Approved IVRS - Inspection :*
06/01/2006 ROOF NAILING Partial Approval IVRS - Inspection :*
1) NAIL ROOF DECKING TO LEDGER
2) NEED NON-? 1" SPACER UNDER POSTS
3) USE 16D 2 1/2".162 DIAMETER NAILS IN LU HANGERS
05/09/2006 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WRONG SIZE NAILS IN HANGERS-NEED SCREWS. SEE PLAN CHECK FOR SIZE. NO NAILING FROM ROOF DECK TO LEDGER, NEED MECHANICAL CONNECTION
2) WRONG SIZE NAILS AT POST TO BEAM HARDWARE SEE SIMPSON CATALOG
3) NEED 1" GAP AT POST TO CONC. INSTALL A SPACER (NON WOOD)
4) ROOF DECK COVERED NO INSPECTION MADE