Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01309
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
07/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) AT INTERMEDIATE INSPECTION NEED SW3-BLKS 2) 2ND FLOOR BEDROOM SHEAR DRYWALL BLOCKED 3) OK TO COVER EXT. |
|
07/07/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1. WIND BRACING 1ST & 2ND FLR EAST WALL 2. HEADER SUPPORT MSTR HALL 3. TWO SW3 MIDSPAN, BLKS FOR SHEAR (ABOVE GARAGE) (MSTR. BED) 4. COIL STRAPS AT 4'0" AT 2ND FLR. CRIPPLE WALL 5. BLK. BROKEN OSB MARKED ON FLR, FAMILY ROOM ABOVE, OSB FLR. ABOVE GARAGE. 6. MST40 STRAP DBL BLK AT GARAGE BEAR PAGE 11 |
|
06/25/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WEST WALL GARAGE MISSING CLIPS TOP AND BOTTOM 2) FRONT WINDOW KING STUD NOT CLIPPED 3) CORNER OF TOP PLATE NOT CABIN TIED NEED TO BE STRAPPED 4) FRONT ENTRY HEADER NOT CLIPPED AT BOTTOM 5) ANY BREAKS ON DBL TOP PLATE MUST BE STRAPPED 6) KING STUDS ON S/W CORNER WINDOW MISSING CLIPS 7) TOP PLATE NEEDS STRAPS 8) STOPPED INSPECTION |