Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM01300

Parcel: 141095460


Addresses:

6356 E STAR MICA ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM01300

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/23/2007 FRAMING Approved IVRS - Inspection :*
01/22/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER JIM
01/10/2007 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) 3/D6 NOT COMPLIED WITH AT GARAGE SHEARWALL
2) 1/D6 MISSING OSB SHEAR
3) 4 X 6 CARRING STAIRS SUPPORTED BY SINGLE 2 X 4 POST AT STAIR
4) PLUMBING SUPPORT OUT OF WALL
5) FIRE BLOCK CHASE BY WATER HEATER
6) A/C CONDENSATE MUST DRAIN IN CONSPICIOUS LOCATION
7) STAIR RISE EXCEEDS 3/8" DIFFERENCE IN RISE AND 7 3/4" RISE EXCEEDS
8) NAIL SECOND FLOOR PLATES AT 16" ON CENTER
9) DUCT KINKED AND INSULATION TORN M/BATH
10) A/C COPPER CARPORT BE IN CONTACT WITH GALVANIZED B-VENT
11) STOPPED INSPECTION-TOO MANY ITEMS