Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM01300
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/23/2007 | FRAMING | Approved | IVRS - Inspection :* | |
01/22/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JIM |
|
01/10/2007 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) 3/D6 NOT COMPLIED WITH AT GARAGE SHEARWALL 2) 1/D6 MISSING OSB SHEAR 3) 4 X 6 CARRING STAIRS SUPPORTED BY SINGLE 2 X 4 POST AT STAIR 4) PLUMBING SUPPORT OUT OF WALL 5) FIRE BLOCK CHASE BY WATER HEATER 6) A/C CONDENSATE MUST DRAIN IN CONSPICIOUS LOCATION 7) STAIR RISE EXCEEDS 3/8" DIFFERENCE IN RISE AND 7 3/4" RISE EXCEEDS 8) NAIL SECOND FLOOR PLATES AT 16" ON CENTER 9) DUCT KINKED AND INSULATION TORN M/BATH 10) A/C COPPER CARPORT BE IN CONTACT WITH GALVANIZED B-VENT 11) STOPPED INSPECTION-TOO MANY ITEMS |