Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/11/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* REFEE PRIOR INSPECTION NOT COMPLIED WITH. |
|
| 05/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | PROVIDE RSP4'S AT SHEARWALL GARAGE | |
| 05/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. REMOVE AND REPLACE INADEQUATE SIZED SHEETING ON SHEAR WALLS. 2. SHEAR WALLS NOT REACHING TOP PLATE. 3. SHIM UNDERSIZED STUDS. 4. STRAP GABLE ENDS. 5. BANG PLATES WHERE NEEDED. 6. NO ROOF ACCESS. |