Permit: T06CM01289

Parcel: 13322471B

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
05/17/2006 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
OK FOR CEILING TILES
04/27/2006 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
EXHAUST DUCT & FANS IN RESTROOMS OK TO SHEETROCK. WILL CHECK SUPPLY FROM OVERHEAD.
PROVIDE DUCT SMOKE DETECTORS WITH AUDIBLE & VISIBLE ALARMS.
USE SHEET METAL HANGER STRAPS ON ALL SHEET METAL DUCTS.
NYLON STRAP IS ONLY TO BE USED ON FLEX DUCT.
PROVIDE MIN. R-5 INSULATION ON ALL DUCT INSIDE THE BLDG. 1 1/2" FOIL WRAP IS R4.2 INSTALLED.