Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM01287

Parcel: 140260800

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T06CM01287

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
04/13/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
BACKFILL IN ACCORDANCE WITH UPC SEC 315.4
"TRENCHES SHALL BE BACKFILLED 12" ABOVE TOP OF PIPING W/CLEAN EARTH WHICH SHALL NOT CONTAIN STONES, BOULDERS, CINDERS, FROZEN EARTH, OR CONSTRUCTION DEBRIS."
04/12/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SHADING
SLOPE
SUPPORT