Permit: T06CM01270

Parcel: 136261290

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
08/25/2006 MECHANICAL - FINAL Approved IVRS - Inspection :*
08/24/2006 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
CONDENSATE HOSE OR FAN COIL IS KINKED.
DRAIN LINES MUST HAVE A MIN. 1/8" PER FT. SLOPE.
CONDENSATE LINES ON ROOF NEED LATEX PAINT.
VENTS MUST BE DOWNSTREAM OF THE TRAP.
LOW VOLTAGE WIRE MUST BE IN CONDUIT.
PROVIDE SCREEN IN T-TOP ON ROOF.