Permit: T06CM01265

Parcel: 11617149A


Addresses:

1037 W SPEEDWAY BL

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/27/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/20/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL 2 NAILS TOP AND BOTTOM WIND BRACING (DO NOT DRY IN ROOF UNTIL 1025 APPROVED)
2) INSTALL TRUSS BRACING PER APPROVED TRUSS DRAWING
3) INSTALL RETRO FIT HOLDOWNS-SPECIAL INSPECTION REQUIRED
4) INSTALL ADDITIONAL H2.5'S LEDGER TO STUDS AND TRUSSES
05/17/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ADDITIONAL WIND BRACING REQUIRED WEST SIDE WALL
2) STOPPED INSPECTION
05/01/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. STRAP HEADERS AT BEARING.
2. INSTALL 2 NAILS TOP AND BOTTOM WIND BRACING.
3. INSTALL WIND BRACING ALL CORNERS EACH DIRECTION.
4. PLAN CALLS FOR 2X10 RAFTERS GARAGE.
5. A35'S INCORRECTLY INSTALLED
6. INSTALL DRAG STRUT WITH BLOCKING 4 PLACES EACH END OF HOUSE.
7. FRONT PORCH CALLS FOR 4X10 RAFTER
8. INSTALL H2.5'S INTERIOR BEARING TRUSS TO PLATE, PLATE TO STUD STUD TO BOTTOM PLATE.
9. NEED TRUSS DRAWINGS TO DETERMINE LATERAL
BRACING & BEARING POINTS. HOLDDOWN MISSING LEFT SIDE GARAGE.
10. STOPPED INSPECTION!