Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM01237

Parcel: 140261510

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T06CM01237

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
04/11/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
THE CORRECTIONS HAD NOT BEEN MADE, BUT YOUR MASON AND I CORRECTED 3 SECTIONS ON PIPING THAT DID NOT HAVE THE CORRECT SLOPE.
CHECK EVERY SECTION WITH A GRADE LEVEL PRIOR TO CALLING FOR INSPECTION.
04/07/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
BACKPITCH PRESENT AT UPPER TERMINAL.
CLOSET TRAP ARM HAS BACK PITCH
TWO SECTIONS OF DRAIN PIPING HAVE ONLY 1/8" PER FOOT SLOPE.
04/06/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE 2% SLOPE THROUGHOUT