Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/26/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1. ALL CORRECTIONS HAVE BEEN MADE OK 2. PLUMBING FINAL OK OK TO COVER ALL AREAS. 3. OK FOR C OF O PENDING ANY OTHER INSPECTION. |
|
| 04/20/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* DOOR LOCKED 245 PM |
|
| 04/19/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* HORIZONTAL CHANGE OF DIRECTION AND VERTICAL TO HORIZONTAL CHANGE OF DIRECTION ON CAST IRON NEED TO BE MADE WITH MEDIUM SWEEPS NOT 1/4 BENDS. OPEN FRONT TOILET SEAT REQUIRED IN PUBLIC FACILITY PLACE SUPPORT UNDER EXPANSION TANK, 7/8 STRUT LOOKS LIKE IT WOULD WORK. |
|
| 04/12/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. HAVE ELECTRICAL INSPECTION ADDED TO PERMIT. ELECTRICAL WIRING TO WATER HEATER. 2. PROVIDE ACCESS PANEL FOR AAV. 3. PROVIDE ACCESSIBILITY FOR SINK CLEAN-OUT. INSTALL COUNTER SINK TAPPED CLEANOUT PLUG WITH 5/16" MACHINE SCREW. 4. ABS MAY NOT BE INSTALLED IN EXPOSED EXTERIOR LOCATION. |
|
| 04/10/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* NOT READY -- NO ACCESS |
|
| 03/31/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. NOT INSTALLED PER PLAN - WORK COVERED WITHOUT INSPECTION. 2. ELECTRIC WATER HEATER HAS NO EXPANSION TANK. ELECTRIC WATER HEATER WILL NEED TO HAVE MECHANICAL INSPECTOR TAKE A LOOK. |