Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM01231

Parcel: 119421420

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/15/2006 FRAMING Approved IVRS - Inspection :*
06/14/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REPLACE STUD EAST GARAGE
2. FHA STRAP OVER-NOTCHED @ TOP PLATE
3. IN GARAGE EXTEND UFER
4. COMPLETE MECH
5. DWV
6. FHA STRAP W/16d NAILS @ DRYER VENT.
7. STOPPED INSPECTION