Permit: T06CM01212

Parcel: 140261530

Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Permit Number - T06CM01212

Inspection Description - PLUMBING - YARD WTR LINE/TEST

Inspection Status - Approved

Date Description Inspector Results Comments
04/14/2006 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
04/13/2006 PLUMBING - YARD WTR LINE/TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE SHADING
REMOVE TIE WIRE FROM TUBING.
COPPER CANNOT TOUCH METAL
REMOVE EXCESS FLEX FROM SOLDIER JOINTS
REAM ALL COPPER JOINTS.
ROUTE YARD PIPING SO THAT COUPLINGS OR TRANSITION FITTINGS ARE NOT UNDER DRIVEWAY SLAB.