Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01172
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/07/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO DRY IN ROOF 2) FINISH NAILING OSB TO LEDGER AT GARAGE 3) FINISH NAILING A.35 TAB TO LEDGER 4) GABLE END TRUSS TOE NAIL 12" BOTTOM CHORD TO TOP OF TRUSS |
|
| 05/25/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NEED ANSWER ON GABLE TRUSS STIFFINING 2) MOVE 3 BAY HEADER TO OUTSIDE 3) NEED TO SLOPE CRICKET AT GARAGE AWAY FROM WALL 4) HEADER NORTH WALL 2ND BEDROOM FROM FRONT NOT SIZED PER PLAN 5) NEED OSB AT GABLE END FOR FLASHING BACKING 6) BLOCK GARAGE OSB AT EDGE AND NAIL |