Permit: T06CM01133

Parcel: 134111720


Addresses:

8107 E ELI ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
04/05/2006 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
04/04/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUND WIRES MUST BE TWISTED TOGETHER AND SECURED WITH SPLICE CAP OR GREEN WIRE NUT
2) WIRES MUST BE STAPLED WITHIN 8" OF BOXES AND MUST BE SECURED TO PREVENT DAMAGE FROM SHEETROCK
3) DEVICES NEED NOT BE INSTALLED AT INTERMEDIATES
4) ALL METAL BOXES MUST BE GROUNDED
5) FOR SIDING INSPECTION, ADD 24" STRAPS SPANNING PLATES ON DIAGONAL WALL AND ADD H2.5'S TO RAFTERS