Permit: T06CM01127

Parcel: 11450001A

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/20/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
03/30/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
PVC WATER PIPING BELOW GROUND OK TO COVER
NEED TO SEE CONNECTION AT PVB
INSTALL TRACER WIRE, USE CLEAN FILL
NEVER TEST PVC W/AIR
09/19/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
TYPE L COPPER W/BRAZE JOINTS BELOW SLAB OK
100 PSI TEST OK
USE CAUTION BACKFILLING AROUND ANNEALED JOINTS