Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01114
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/14/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | ||
06/19/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH PREVIOUS INSPECTION |
|
06/16/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER SUPER |
|
06/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR TO CONTINUE BEHIND WALL AT ENTRY 2) P3 NAILING REQUIRES 3" ON CENTER EDGE NAILING 3) SHEAR REQUIRED BEHIND LIVING ROOM POP OUT 4) DETAIL 20/SD4 NOT COMPLIED WITH 5) ANCHOR BOLTS REQUIRED 16" ON CENTER PER S-1 NOTE "C" 6) STOPPED INSPECTION |