Permit: T06CM01111

Parcel: 140294510

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/19/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/16/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2 NAILS TOP AND BOTTOM WIND BRACING
2) WIND BRACING REQUIRED EACH CORNER BOTH WAYS AND MAX. 25' OF RUN
3) NEED LADDER TO INSPECT ROOF
4) CROSS BRACE ROOF TRUSSES EACH END AND MAX. 25' OF RUN
5) INSTALL APPROVED JOIST HANGERS PORCH RAFTERS TO LEDGER
6) STOPPED INSPECTION
05/11/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*