Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
10/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CHECK ANCHOR BOLT SPACING 2) STRAP BEAM IN GARAGE TO POST 3) 2ND FLOOR SHEAR STRAPS AROUND FLOOR TRUSS 4) BLK FLOOR UNDER GIRDER POST-W. SIDE AND E. SIDE 5) FULL BEARING REQUIRED UNDER GLU LAM AND STRAP TO POST 6) COMPLETE H2.5 ON BLKS 7) DBL STUD UNDER STAIR BEAM AND STRAP TO POST 8) OBTAIN ENGINEERING FOR CUT SLAB-X 2 9) APPROVED TO LATHE |