Permit: T06CM01080

Parcel: 141096280

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM01080

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/11/2006 FRAMING Approved IVRS - Inspection :*
12/06/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LATH NOT STAPLED HIGH FRONT GABLE
2) REMOVE LATH AT KITCHEN 3" CLEANOUT
3) ITEMS 2 & 4 OF 11/21/06 INSPECTION NOT DONE
11/21/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OUTSIDE HOSE BIBS REQUIRE NON REMOVEABLE ANTI-SIPHON VALVES
2) W/H B-VENT MUST RISE AT A MINIMUM 30 DEGREE PITCH
3) GARAGE SHEARWALL 8' SEAM NOT NAILED
4) 3' STACK CLEANOUT HAS STUCCO LATHE COVERING W/O CAULK (KITCHEN)
5) WINDERS MUST BE 6" ON NARROW END
6) STAIRS MUST BE 36" FINISHED
7) FIRE CAULK S.W. BEDROOM CHASE
8) NAIL SHEARWALL BOTTOM PLATES PER PLAN
9) FIRESTOP DUCT CHASE M/BATH
10) NO RISER
11) STOPPED INSPECTION-TOO MANY ITEMS