Permit: T06CM01079

Parcel: 141096270

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01079

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/05/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/23/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) THE OFF SITE AND ON SITE FRAMING OF THIS HOUSE WAS DONE USING 3" X .131" 10D FRAMING NAILS-16D NAILS ARE REQUIRED. HAVE ENGINEER OF RECORD PROVIDE CITY OF TUCSON AN EVALUATION AND RESOLUTION TO THE PROBLEM
2) TECO NAILS CANNOT BE USED TO SECURE HARDWARE THRU OSB. YOU MUST USE 8D COMMON OR SINKERS
3) SAFETY BRACES MUST USE 16D NAILS
4) PORCH LEDGER REQUIRES BLOCKS, H2.5 CLIPS AND HAVE LEDGER DIRECTLY CONNECTED TO STUDS 15/D7