Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/29/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/27/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MINIMUM STAIR WINDER WIDTH ALLOWED IS 6" FROM BULL NOSE TO BULL NOSE PRESENTLY 3" |
|
| 11/07/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MAXIMUM ALLOWED DIFFERENCE INSTAIR RISE 3/8" EXCEEDED 2) MINIMUM WINDER STAIR WIDTH 6" 3) DRYER DUCT OUT OF WALL 4) FIRESTOP N.W. BEDROOM CHASE 5) REPLACE DAMAGED W/H B-VENT IN CHASE 6) NAIL F7 TRUSS H2.5 7) BLOCK DUCT BOOT DINING ROOM |
|
| 10/23/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1. WIRING NOT COMPLETE AT SVC PANEL 2. WATER HEATER "B" VENT CANNOT TERMINATE IN DEAD SPACES. 3. TOILET MUST VENT ABOVE THE CENTER LINE OF THE DRAIN 4. EXHAUST FAN DUCT BROKEN 5. NO GAS BOND -- STOPPED INSP. TOO MANY ITEMS |