Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM01073

Parcel: 141096210

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM01073

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/29/2006 FRAMING Approved IVRS - Inspection :*
11/27/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MINIMUM STAIR WINDER WIDTH ALLOWED IS 6" FROM BULL NOSE TO BULL NOSE PRESENTLY 3"
11/07/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MAXIMUM ALLOWED DIFFERENCE INSTAIR RISE 3/8" EXCEEDED
2) MINIMUM WINDER STAIR WIDTH 6"
3) DRYER DUCT OUT OF WALL
4) FIRESTOP N.W. BEDROOM CHASE
5) REPLACE DAMAGED W/H B-VENT IN CHASE
6) NAIL F7 TRUSS H2.5
7) BLOCK DUCT BOOT DINING ROOM
10/23/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1. WIRING NOT COMPLETE AT SVC PANEL
2. WATER HEATER "B" VENT CANNOT TERMINATE IN DEAD SPACES.
3. TOILET MUST VENT ABOVE THE CENTER LINE OF THE DRAIN
4. EXHAUST FAN DUCT BROKEN
5. NO GAS BOND -- STOPPED INSP. TOO MANY ITEMS