Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T06CM01066
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/17/2007 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/16/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROTECT ROOF PENETRATIONS 2. #10 ROMEX (DRYER) DOES NOT FIT IN CAVITY DUE TO DRYER OUTLET VENT (MIDDLE UNIT) |
|
| 08/14/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ROOF PENETRATIONS FOR AC FEEDER REQUIRES CONDUIT SLEEVE 2. TOP WOODEN 2X4 PLATE ABOVE PANEL - USE NAIL PROTECTIVE PLATES WHERE LESS THAN 1 1/4" 3. STAPLE ALL ROMEX WIRES ABOVE PANEL 4. #12 ROMEX BEHIND DRYER VENT IS FORCED TO STICK OUT OF WALL, ALL UNITS 5. ALL EXTERIOR BOXES TO BE PLACED TO MEET O/S DEPTH OF WALL |
|
| 08/10/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COULD NOT LOCATE PLANS/PERMIT |