Permit: T06CM01063

Parcel: 115170980

Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T06CM01063

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
05/07/2008 SITE - SEWER Approved IVRS - Inspection :*
02/12/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
01/25/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
AIR TEST BY TONY TSANG WITNESSED BY C.O.T
01/11/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
1. 100' INTERVAL CLEANOUTS ADDED OK
BE SURE AND REDLINE LOCATION ON PLAN
OK TO COVER SUBJECT TO VERIFICATION OF GRADE AND TEST
01/08/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
1. WILL REQUIRE 4" CLEANOUTS AT EVERY 100' DEVELOPED LENGTH
2. OK TO COVER SDR 35 SUBJECT TO VERIFICATION OF GRADE AND TEST
3. DO NOT MAKE ANY HOUSE CONNECTIONS UNTIL AUTHORITY TO DISCHARGE FROM PDEQ AND C.O.T APPROVAL
4. CALL IN SITE SEWER FOR ALL UNITS
01/04/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
1. 6" SDR 35 FROM P.L CLEANOUT TO UPPER
TERMINAL CLEAN OUT OK TO COVER SUBJECT TO TEST AND VERIFICATION OF GRADE.
2. 4" SDR 35 BRANCH TO END OF FIRST BLDG. ON SOUTH SIDE OK SUBJECT TO TEST AND VERIFICATION - NO UNITS TIED IN
01/03/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
DAVID STEWART - AL LACOQ
TONY TSANG - TSANG ENGINEERING
FRED KING - KING EXCAVATING
RICK MYERS - C.O.T

SITE SEWER PRE-CON

6" X 18" DIP INSTALLED FROM MANHOLE LOCATION TO CURB OK TO COVER SUBJECT TO TEST AND VERIFICATION OF GRADE
01/02/2008 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
NOT READY -- CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE
12/31/2007 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
SCHEDULE PRE-CON FOR WEDNESDAY
LEAVE NAME AND NUMBER WHEN SCHEDULING