Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM01063
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/29/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/23/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SECURE WATER STUB OUTS PERPENDICULAR W/WALL OK TO COVER WALLS 03035 LEFT OPEN FOR MATERIAL SPECIFICATIONS AND CLOSET FLANGE INSP. |
|
| 08/17/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 08/15/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - DWV OK - 18" OF METALLIC PIPE REQUIRED AT WATER SERVICE SEE PLUMBING SPECS L CU SPECIFIED AND 1" FIBERGLASS INSULATION. - PROVIDE WATER PRESSURE GAUGE - SECURE SHOWER VALVES - SECURE PEX TO BLOCKING W/APPROVED CLAMPS NOT ZIP TIES - SECURE WASHER BOX VALVES - CORRECT PEX AT LAV UNIT 2 - SUPPORT HORIZONTAL GAS PIPING - SUPPORT NEAR ROOF PENETRATIONS - WHS INSTALLED ON A WOOD PLATFORM REQUIRE A PAN - SECURE SUPPORTS AT VENTS ABV TUBS CLOSET FLANGES SHALL BE INSPECTED AFTER FINISHED FLOOR. FLANGES SHALL BE SECURED TO FF |