Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM01058
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Not ready for Inspection
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. VENTS TO BE INSTALLED LEVEL OR SO DESIGNED AS TO DRAIN BACK TO THE ORIGINATING FIXTURE (BACK PITCH NOT PERMITTED). 2. DRAINAGE PIPING TO BE INSTALLED AT 2% PITCH 3. SUPPORT OVERHEAD HORIZONTAL VENT 4. HAVE 03050 GAS PRESSURE TEST ADDED TO YOUR PERMIT AND CALL TEST UNDER THIS CODE. |
|
| 07/25/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 07/24/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 07/20/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 07/10/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. HOSE BIBBS OK CLOSET FLANGES OK 2. WOMENS RESTROOM: CLOSET FLANGES OK COPPER OK N/H DWV THRU ROOF OK 3. OK TO INSULATE HOT OK TO COVER ALL AREAS |
|
| 07/05/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. NEED TO SEE HOT & COLD HOSE BIBB INSTALLED. 2. N/H DWV OK COPPER OK WITH EXCEPTION NEED TO SEE CLOSET FLANGES. THIS INSPECTION IS FOR MENS RESTROOM |
|
| 06/22/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNDERGROUND COMPLETE, OK TO COVER ALL AREAS AS HIGHLIGHTED ON PLAN - OK TO COVER. |
|
| 06/16/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. ACID WASTE IN LAB 501 AS INITIALED ON P-1 OK 10 FOOT HEAD WATER TEST OK OK TO COVER |
|
| 06/08/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. DISCUSSED REQUIREMENTS FOR REPLACING/REUSING EXISTING COPPER WATER EMBEDDED IN MASONRY. |