Permit: T06CM01051

Parcel: 141095260

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/29/2006 FRAMING Approved IVRS - Inspection :*
11/27/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BEARING WALL NOT ANCHORED AT GARAGE ENTRY THIRD REPEAT
2) MINIMUM STAIR WIDTH AT WINDERS 6" FROM BULL NOSE TO BULL NOSE. PRESENTLY 4 1/2"
11/22/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OK TO INSULATE
2) ITEM 2 & 5 OF 10/23/06 NOT DONE
10/23/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. GARAGE -- TOILET NOT PROPERLY VENTED MUST VENT ABOVE CENTER LINE OF DRAIN.
2. STAIR WINDER MUST BE AT LEAST 6" ON NARROW END
3. T6 & T7 TRUSSES MISSING BRACES -- RAT RUNS
4. STAIRS MUST BE A MINIMUM 36" WIDE
5. BEARING WALL NOT ANCHORED AT GARAGE ENTRY
6. SHEAR WALLS MISSING ANCHOR BOLTS SEE PLAN FOR AMOUNT.
7. KITCHEN SINK MUST VENT TO ROOF - SEE PLAN
10/04/2006 FRAMING Not ready for Inspection IVRS - Inspection :*