Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/01/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING SHEAR PANELS AT GARAGE 2) STRAP GLU LAM AT GARAGE PER DETAIL 10/D5 |
|
| 04/25/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 20/D4 GABLE END HINGE BRACES 48" ON CENTER 6'-0" LONG 2) MISSED NAILING ON GARAGE 3) VERT. WALL GARAGE TO HOUSE AT ROOF NEED FLASHING BACKING 4) NO TRUSS DRAWING ON SITE, CHECK FOR 3 PT BEARING & LATERAL BRACES 5) MISSED SHEAR WALL OSB AT NORTH EAST GARAGE 6) MISSED TWO STH10'S AT SOUTH WALL 7) AT EACH SIDE OF GARAGE INSTALL STRUCTURAL STRAP AT HEADER 13/D5 |