Permit: T06CM01020

Parcel: 141317190


Addresses:

9092 S OLD OAK CT


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01020

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/02/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/31/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) COMPLETE #6 FROM INSPECTION DONE ON 5/15/06
2) OK TO DRY IN ROOF AND WALLS
05/18/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SEE ITEMS LAST INSP - PLUS LEDGER NOT NAILED TO ROOF DECK AT GARAGE.
2. PLAN CALLS FOR DBL. 2X8'S AT 3 BAY TRUSSES BEAR ON OUTSIDE WALL WHICH HAS NO HEADER?
05/15/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ROOF NOT NAILED OR SUPPORTED AT EDGES IN FIELD, SEE BLACK MARKS
2) TWO BROKEN TRUSSES, ONE DAMAGED PLATES
3) NEED TO VERIFY WHAT, DETAIL APPLIES TO GABLE ENDS, STIFFNER, HINGE BRACING
4) NAIL PANELS/SHEAR TO ROOF
5) USE CORRECT NAILS IN HANGERS, 10D AT GARAGE FRONT, 16D AT GARAGE INTER HANGERS
6) A3.5'S REQUIRED AT LEDGER INTERIOR GARAGE
7) MISSING RAT RUNS SEE TRUSS DRAWINGS
8) NAIL OFF HORIZONTAL JOINT AT ENTRY