Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06CM01015
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/12/2006 | PLUMBING - FINAL | Approved | ||
| 09/08/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* WATER HEATER AND WH SAFETY DEVICES ARE OK INSULATE HW AND HW RECIRC PIPING AT WH HB VAC BREAKERS MISSING MIXING VALVE AT FILE PROCESSOR MISSING. PROVIDE BACKFLOW CERT FOR INTERNAL CLEANOUT PLUGS FOR SINKS SHALL BE REMOVABLE WITHOUT HAVING TO CUT SHEET ROCK |
|
| 09/06/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLUMBING FIXTURES DO NOT MEET PLAN SPECS, SOME EXAMPLES ARE WCS, LAVS, LAV FAUCETS, MOP SINK FAUCET. LOOSE KEY ANGLE STOPS. PROVIDE LETTER FROM ENGINEER FOR THIS PROJECT, ALLOWING BRAND OF FIXTURES INSTALLED. ALL FIXTURES SHALL BE SEALED WHERE CONTACTING FLOOR, WALLS AND COUNTER TOPS. THIS INCLUDES ALL SINKS, LAVS & WCS SUPPORT EXP. TANK TERMINATE T&P INSTALL HB VAC BREAKERS LOCATE 3" FCO, END OF LINE CLEANOUT SHOWN ON PLAN. TRIM OUT ALL CLEANOUTS MAKE THEM ACCESSIBLE USE PLUGS LISTED TO RECEIVE SCREW FROM COVER. NOT TAPPING PLASTIC PLUGS PLUMBER THAT INSTALLED NEW RP IS TO OBTAIN PERMIT FROM TUCSON WATER BACKFLOW SECTION. |