Inspection History Details
Inspection Status: Approved
Inspection History: STUCCO MESH
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/05/2007 | STUCCO MESH | Approved | IVRS - Inspection :* | |
| 02/13/2007 | STUCCO MESH | Partial Approval | IVRS - Inspection :* 1) SEAL PENETRATIONS/EXCEPT ENTRY WINDOW 2) BLOCK BETWEEN HIGH/LOW COMBUSTION GARAGE 3) FIREBLOCK MISSING GARAGE NORTH WALL A/C LINE 4) BLOCK MECH PLENIUM 5) NO WATER TEST DWV OR POTABLE WATER 6) PROVIDE 12" CLEARANCE PEX FROM CMU'S 7) NAIL PROTECT MASTER VANITY ABS 8) MISSING SMOKIE MASTER HALLWAY 9) DAMAGED FIREBLOCK MASTER HALLWAY 10) MISSING AB AND BLOCKING INTERIOR SHEARWALLS 11) MISSING BOLTS HOLDOWNS AND AB'S THROUGHOUT 12) FIRESTOP FIREPLACE FLUE |
|
| 02/09/2007 | STUCCO MESH | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MOVE EXTERIOR RECEPTACLES OU OF POP OUTS 2) REPLACE GAS GAUGE 3) VACUUM BREAKERS NEEDED ON HOSE BIBS 4) SUPPORT BOTH SIDES OF 4 GANG SWITCH BOXES 5) SEAL VAPOR BARRIER 6) FILL DWV 7) FIRESTOP AROUND LINE SET 8) 1" CLEARANCE TO COMBUSTIBLES AROUND B-VENT 9) BLOCK CEILING AT MECH UNIT 10) STOPPED INSPECTION-NOT READY |
|
| 01/08/2007 | STUCCO MESH | Not ready for Inspection | IVRS - Inspection :* |