Permit: T06CM01004

Parcel: 10603079C

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
12/19/2006 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
1. INSULATE ALL SPIRAL DUCTS & SHEETMETAL FITTINGS.
2. SEAL ALL JOINTS ON METAL DUCTS.
3. DUCT SMOKE DETECTORS MUST BE AHEAD OF ALL
DUCT INLETS.
4. SUPPORT FLEX DUCTS EVERY 5' & USE 1 1/2" MIN. HANGER STRAP.
12/01/2006 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
EXCLUDES FLEX DUCT THRU 1 HR. WALL AT LINE K
11/06/2006 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
CAN ONLY TERMINATE CONDENSATE INTO RESTROOM/BATHROOM LAV/SINK
NOT ANY KITCHEN, KITCHENETTE