Permit: T06CM01004

Parcel: 10603079C

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM01004

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/21/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1. OK TO COVER ALL AREAS
CLOSET FLANGES OK
11/15/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CLOSET FLANGES TO BE SCREWED TO THE FLOOR
10/24/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. ABOVE CEILING OK
2. INSTALL "DUTCHMAN" ON RECESSED CLOSET BINS
DO NOT SET WATER CLOSETS UNTIL RE-INSPECTED
3. UNABLE TO LOCATE PERMIT OR APPROVED PLAN
10/20/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
10/19/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. SUPPORT ALL TURN OUTS
2. SUPPORT OVERHEAD AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES THRU NO MORE THAN 4' BETWEEN HANGERS.
3. USE APPROVED STRAPS.