Permit: T06CM00991

Parcel: 131010460


Addresses:

5028 E 22ND ST #106

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/01/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/07/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
PROVIDE LETTER STAMPED BY ENGINEER GIVING OK FOR WIRSBRO (PEX) WATER PIPING IN PLACE OF COPPER OVERHEAD.
07/06/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE ALL NOTES NO PLANS OR CONTACT PERSON ON SITE.
06/09/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CLOSET FLANGES OK
1. SEE NOTE #2 FROM 6/5/06 INSPECTION. SEE ALL NOTES 6/5/06
2. INSTALL WATER HEATERS PER PLAN OR HAVE PLAN REVISED & APPROVED TO SHOW YOUR INSTALLATION.
NOTE: PARTIAL APPROVAL IS NOT AN APPROVAL.
3. PROVIDE CORRECT BACKFLOW PROTECTION FOR EQUIPMENT AT REAR OF BUILDING.
4. HAVE A CONTACT PERSON ON SITE FOR NEXT INSPECTION OR EXPECT REFEE.
06/05/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT THRU ROOF OK
WATER PIPING NORTH RESTROOM IN WALL OK
1. SECURE CLOSET FLANGES USING BRASS OR STAINLESS FASTENERS PRIOR TO SETTING STOOLS WITH INSPECTION.
2. WATER PIPING OVERHEAD REQUIRED TO BE T/L COPPER PER SPEC.
3. CORRECT INSTALL OF SOUTH WATER HEATER WITH APPROVED PLAN SHALL BE REQUIRED.
03050 -- PLAN CALL FOR GAS TO WATER HEATER AT SOUTH LOCATION.
OK FOR WALLS.
04/17/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*